marco: Ultrasonic Sensor

ulm/s12me

[Link to marco Home Page]

Contact Ultrasound in Liquids PDF Version Deutsche Version




Picture: ulm/s12me Ultrasonic Sensor
The Ultrasonic Sensor ulm/s12me and the ulm/... controller and evaluation unit measure distance in liquids using the pulse echo method. A typical application is to determine the piston position in a hydraulic accumulator.

The ultrasonic pulse emission, required to measure the transit time, is optimized for use in hydraulic fluids and water with special impedance matching.

With the reference reflector connected to the sensor, the unknown measured distance is compared with the distance to the reflector, so influence of temperature or pressure changes on the impulse transit time are eliminated.

The only materials on the mounted sensor that are in contact with the fluid medium are the sealing ring, stainless steel and a special water and oil resistant epoxy resin.

Features:
Recommended Ultrasonic Frequency
500kHz
Typical Input Voltage
approx. ± 15Vss
Maximum Output Parameters
U = 30V
of Connected Circuit:
I = 100mA

P = 750mW
Maximum Measuring Distance
approx. 5m (depending on medium characteristics

and installation environment)
Pressure Resistance
> 500bar
Operating & Storage Conditions
-20 to +60°C
Cable Length
1m (refer also to connection note below)
Application Note:

The reliability and range of the method to measure the distance of the surface reflecting the ultrasonic waves greatly depends on the homogenity of the medium and on the characteristics of the controller and evaluation electronics. Conditions of installation should be discussed with marco in detail prior to initial operation.

Our separate application notes must be observed prior to operation!

Refer to doc:D/ulm/man/003

Connection:

Picture: ulm/s12me mounted with flange and screw connection


If the distance between sensor and electronics is over 1m the sensor cable must be shortened as necessary and connected to an extension cable, refer to cable type below.

Mounting with flange ulm/s12me.fl and screw connection ulm/s12me.pg9:

[] Put the flange onto the screw connection
[] Insert the cable through the screw connection
[] Shorten the sensor cable
[] Connect the cable to the sensor cable (e.g. by crimping or soldering)
[] Screw connection onto the sensor

Cable Recommendation:
Length:
Cable Type:
< 30m
IBM Twinax, 2 symmetrical leads, shielded
< 5m
Telephone grade twisted pair
< 1m
Directly connect sensor cable


Order Number
Release
Description
ulm/s12me
1.0
Ultrasonic Sensor
ulm/s12me.fl
1.0
Flange
ulm/s12me.pg9
1.0
Screw Connection
ka/ulm.twinax
1.0
IBM Twinax Cable




Contact Ultrasound in Liquids PDF Version Deutsche Version

marco Systemanalyse und Entwicklung GmbH
Hans-Böckler-Str. 2 . D-85221 Dachau
Tel (+49) [0] 8131 5161 0 . Fax (+49) [0] 8131 5161 66
http://www.marco.de/E/D/ulm/s12me/001.html - Rev. 1.3 (2004-06-24)