marco: Single-Channel ULM System

ps/ulm/esd/a

[Link to marco Home Page]

Contact Ultrasound in Liquids PDF Version Deutsche Version




Picture: ps/ulm/esd/a


The ps/ulm/esd/a system combined with the ulm/s12me ultrasonic sensor is used to measure distance in liquids, e.g. the piston position in hydraulic cylinders.

Housing and Installation

The electronics, including signal processor, LCD-display, analog and switch outputs, are fitted in a plastic housing with a degree of protection IP65. The housing can either be mounted directly on a 35 mm mounting rail or screwed to a wall. If the system replaces its predecessor ulm/es/b4, the mounting plate ps/nt:3.09174 can be used to screw the unit to the existing holes.

Connections

External cables are connected via PG-screw connections on the bottom of the housing. The wires are connected to screw terminals inside the housing. The terminals for 1.5 mm˛ are marked for easy installation.

Sensor Cable Connection

Twinax (according to IBM specification),
2 symmetrical leads, shielded
Length: <30 m
Also refer to transducer datasheet:
doc:D/ulm/s12me/001

System Settings

Refer to operating instructions:
doc:D/ps/ulm/esd/002

Features
Operating Voltage
24 V nom.

(18-30 Vdc or 15-24 Vac)
Current Consumption
approx. 150 mA
Measuring Range:
3 cm to 500 cm, greater distances on request
Measuring Rate
approx. 15 Hz
Outputs:
Current Output 4-20 mA (corresponding to 0-100 % distance)

5 Potential-free Relay-Switches (with 125 V, 1 A loading capacity),

incl. one error output

4 adjustable Switching Thresholds between 0 and 100 %
Serial Interfaces
RS232 and Current-Loop (without galvanic isolation)
Operator Control
LC-Display 2x8 Characters, 6 Keys
Dimensions:
252.5 x 68 x 136 mm (LxWxH)

Overall Height (with screw connections): 163 mm
Protection Class
IP65

The separate application notes must be observed prior to operation!
Refer to doc:D/ulm/man/003

Picture: Functional Diagram


Pin Assignment
ps/ulm/2b
Pin-VG
Description
TX+
a2
Current Loop TX+, +12V
TX-
c2
Current Loop TX-
RX+
a4
Current Loop RX+
RX-
c4
Current Loop RX-, GND
UB1
c6
Power Supply
UB2
c8
Power Supply, GND
F1
a6

F2
a8

RX
a10
RS 232 RX
TX
a12
RS 232 TX
GNDx
c10
RS 232 GND, GND
Out+
a14
4-20mA Out+
Out-
a16
4-20mA GND
A5
c12
Switch Output 5
B5
c14

R5
c16


ps/ulm/2b
Pin-VG
Description
A4
a18
Switch Output 4
B4
a20

R4
a22

A3
c18
Switch Output 3
B3
c20

R3
c22

A2
a24
Switch Output 2
B2
a26

R2
a28

A1
c24
Switch Output 1
B1
c26

R1
c28

Piezo 2
a30
PE
Piezo 4
c30
PE
Piezo 1
a32
Sensor Connection
Piezo 3
c32


Order Number
Release
Description
ps/ulm/esd/a
1.0
Single-Channel ULM System
ulm/s12me
1.0
Ultrasonic Sensor
ps/nt:3.09174
1.4
Mounting Plate




Contact Ultrasound in Liquids PDF Version Deutsche Version

marco Systemanalyse und Entwicklung GmbH
Hans-Böckler-Str. 2 . D-85221 Dachau
Tel (+49) [0] 8131 5161 0 . Fax (+49) [0] 8131 5161 66
http://www.marco.de/E/D/ps/ulm/esd/001.html - Rev. 1.8 (2006-09-07)