marco: Torque-Block®pa/ptb |
|
|
|
|
|
|
Torque-Block® technical information for customer-specific applications
In a ceramic laminate, separately controllable
drive units are mounted by integrated
electrode-structuring.
Preliminary mechanical stress required for dynamic operation and tensile
strain does not interact with operating functions. The simple structure
and high reliability are achieved by reduction of load on the
outside contact paths as well as absence of complicated eroded flectors.
The transformation of the translation into a tilted angle takes place
directly in the laminate, and can be read at the end of the lever.
Displacement and stiffness can be varied by setting the lever length H, the
block height L and the block section. Hardware components of the
ase/nvs system or of the unit asy/hyw/e deal with
antisymmetric electric control.
Technical Data for a standard Torque-Block®
|
Length L
|
16 mm
|
Width A
|
14 mm
|
Depth B
|
2.5 mm
|
Preliminary mechanical stress
|
1 kN
|
Operating voltage
|
400 V
|
Capacity
|
2 x 0.5 µF
| |
Block-Specific Data
|
Tilt angle
|
±0.17 deg
|
Blocking moment
|
6.8 Nm
|
Tilt stiffness
|
20 Nm/deg
| |
The following applies for a lever with length H = 26
|
Rotation radius R
|
34 mm
|
Displacement |
±100 µm
|
Blocking force
|
200 N
|
Resonance frequency
|
4.4 kHz
|
Resonance frequency with 2 g weight added
|
3.0 kHz
| |
Application
· Valve drives
· One-axis and multi-axes positioning systems
· High-dynamic tilted-mirror systems
|
|
|
|
|
|
marco Systemanalyse und Entwicklung GmbH Hans-Böckler-Str. 2 . D-85221 Dachau Tel (+49) [0] 8131 5161 0 . Fax (+49) [0] 8131 5161 66 |
http://www.marco.de/E/D/pa/ptb/001.html - Rev. 1.12 (2003-09-16)
All Rights Reserved Any questions or comments about this page? webmaster@marco.de |
|