In a ceramic laminate, separately controllable drive units are mounted by integrated electrode-structuring. Preliminary mechanical stress required for dynamic operation and tensile strain does not interact with operating functions. The simple structure and high reliability are achieved by reduction of load on the outside contact paths as well as absence of complicated eroded flectors. The transformation of the translation into a tilted angle takes place directly in the laminate, and can be read at the end of the lever. Displacement and stiffness can be varied by setting the lever length H, the block height L and the block section. Hardware components of the ase/nvs system or of the unit asy/hyw/e deal with antisymmetric electric control.

Technical Data for a standard Torque-Block®
Length L
16 mm
Width A
14 mm
Depth B
2.5 mm
Preliminary mechanical stress
1 kN
Operating voltage
400 V
Capacity
2 x 0.5 µF

Block-Specific Data
Tilt angle
±0.17 deg
Blocking moment
6.8 Nm
Tilt stiffness
20 Nm/deg

The following applies for a lever with length H = 26
Rotation radius R
34 mm
Displacement [Formel/Equation]l
±100 µm
Blocking force
200 N
Resonance frequency
4.4 kHz
Resonance frequency with 2 g weight added
3.0 kHz

Application
· Valve drives
· One-axis and multi-axes positioning systems
· High-dynamic tilted-mirror systems



Contact Piezo Fundamentals PDF Version Deutsche Version

marco Systemanalyse und Entwicklung GmbH
Hans-Böckler-Str. 2 . D-85221 Dachau
Tel (+49) [0] 8131 5161 0 . Fax (+49) [0] 8131 5161 66
http://www.marco.de/E/D/pa/ptb/001.html - Rev. 1.12 (2003-09-16)
All Rights Reserved
Any questions or comments about this page? webmaster@marco.de
[Link to marco Home Page]